ECRI Microelectronics

Convertidores CC DC Mil-COTS de la serie MV24A

1 características de MV24A Series Mil-COTS DC DC Converters

Input voltage range: 18~36V


Typical input voltage: 24V

Output voltage: 3.3V,5V,12V,15V,24V,28V

Input under-voltage lockout

Output over-voltage protection

Fault alarm

Output voltage regulation range: 10%~110%

Logical shutdown function

ZCS/ZVS power structure, PFM control

Can parallel and expand current, 
Accept N+M fault-tolerance model

3000V voltage isolation


2 Ámbito de aplicación de los convertidores de CC-CC Mil-COTS serie MV24A

Para sistemas electrónicos militares y civiles de alta confiabilidad en aviación, aeroespacial, embarcaciones, armamento, radar, ferrocarril, etc.

3 Descripciones de los convertidores DC-DC Mil-COTS de la serie MV24A

Los convertidores DC-DC de la serie MV24C ​​usan una estructura de conmutación suave ZCS / ZVS con control PFM de bajo ruido. La frecuencia de operación puede alcanzar 1MHz. Los pines se pueden reemplazar con productos similares de VICOR. Estos productos aislaron voltaje 3000V. La eficiencia es de hasta 88% y la densidad de potencia es 80W / in3. Las características de esos productos también incluyen bloqueo de entrada / bajo voltaje, protección de sobre voltaje de salida y protección de sobrecorriente de salida.
El diseño y la producción de productos cumplen los requisitos de SJ20668-1998 y las especificaciones del producto (Q / HW32230-2013).

4 Especificaciones técnicas de los convertidores CC-CC Mil-COTS de la serie MV24A

Tabla 2: Condiciones clasificadas y condiciones de funcionamiento

Absolute maximum rating

Operating conditions

+In   -In Voltage:-0.5V~53V;

PC    -In Voltage:-0.5V~7.0V;

PR    -In Voltage:-0.5V~7.0V;

SC    -Out Voltage:-0.5V~1.5V;

Storage temperature:-65~125℃

Welding temperature:       (manual welding)

(wave soldering)

Input voltage: 18~36V

Working temperature(Tc):-55~100℃


tabla 3 (a) características eléctricas


No.

Character

Symbol

Conditions

(Unless otherwisespecified ,-55℃≤Tc≤125℃,VIN=28V±5%)

MV24A3V3M264B

MV24A5M400B

MV24A12M400B

Min

Max

Min

Max

Min

Max

1

Input Transient voltagea/V

VIS

TA=25℃,小于100ms

TA=25℃,less 100ms

-

50

-

50

-

50

2

Input under-voltage

turn-on voltage

VINL-ONT


VINL-OFF


-

17.9

-

17.9

-

17.9

Turn-off voltage

14.8

-

14.8

-

14.8

-

3

Input over turn-off/on voltage

VINL-ON/OFF


36.3

39.6

36.3

39.6

36.3

39.6

4

Inhibitedinput current/mA

IINH

TA=25℃

-

15.0

-

15.0

-

15.0

5

Bias voltage  for PC port/V

VPC

TA=25℃,IPC=1.0mA

5.50

6.50

5.50

6.50

5.50

6.50

6

Current for PC porta/mA


IPC

TA=25℃,VPC=5.5V

1.5

3.0

1.5

3.0

1.5

3.0

7

Inhibitedfunction  for PC port/mV

VINH-PC

TA=25℃

2.3

2.9

2.3

2.9

2.3

2.9

8

Turn-on delay for PC port

Td(ON)

TA=25℃

-

7

-

7

-

7

9

alarm voltage for PC porta/V

peak/V

VA-PC

TA=25℃

Alarm will be turn on when  input under-voltage or input over voltage

-

6.5

6.5

6.5

period/ms

TPC

1

10

1

10

1

10

pulse/μs

WPC

350

450

350

450

350

450

10

Resistance for PC porta/MΩ

RI-PC

TA=25℃

0.9

1.1

0.9

1.1

0.9

1.1

11

Output voltage amplitude for PR/V

Vout-PR

TA=25℃,PR load over 30Ω,capacitance less 30pF

5.7

6.1

5.7

6.1

5.7

6.1

12

Output current for PR port

Iout-PR

TA=25℃

150

-

150

-

150

-

13

Impedance for PR port inputa/Ω

ZI-PR

TA=25℃

375

625

375

625

375

625

14

Input voltage threshold vale for PR porta/V

VI-PR

TA=25℃,Pulse width≥20ns

2.4

2.6

2.4

2.6

2.4

2.6

15

Drive capabilitya/pc

N

TA=25℃,no buffer amplifier circuit

-

3

-

3

-

3

16

Power distribution precision a/%

PE

TA=25℃,load≥10%

-

5

-

5

-

5

17

SC reference voltage/V

Vb-SC

TA=25℃,relative negative output

1.21

1.25

1.21

1.25

1.21

1.25

18

SC alarm voltagea/V

VA-SC

TA=25℃,SC alarm will be turn on when input under-voltage or output over-voltage()

-

0.5

-

0.5

-

0.5

19

Induct offset voltagea/V

VSC

TA=25℃,each terminal<0.25V(induction terminal is closed)

-

0.5

0.5

0.5

20

Isolation voltage(Ac RMS)/V

VISO

TA=25℃,10s

Between input and output

3000

-

3000

-

3000

-

Between input and baseboard

1500

-

1500

-

1500

-

Between output and baseboard

500

-

500

-

500

-

21

Isolation resistance/MΩ

RISO

TA=25℃,add 500V(DC)between input and output, add 500V(DC)between pin and baseboard

10

-

10

-

10

-

22

Output voltage/V

Vout

TA=25℃,full-load

3.267

3.333

4.95

5.05

11.88

12.12

23

Output current/A

Iout


0

80

0

80

0

33.33

24

Voltage regulation/%

Sv

18 36, full-load

-

0.20

-

0.20

-

0.20

25

Load regulation/%

Sin

No-load full-load

-

0.20

-

0.45

-

0.20

26

Temperature coefficient/(%/℃)

Av


-

0.005

-

0.005

-

0.005

27

Output voltage regulation range/%

VTR

TA=25℃,load≥10%

10

110

10

110

10

110

28

efficiency/%

η

TA=25℃,full-load

75.5

-

80

-

85

-

29

Ripple voltage and noise voltage (peak-peak value)/mV

VR

BW≤20MHz,full-load

-

94

-

190

-

250

30

Output over-voltage protection point/V

Vovp

TA=25℃


4.14

4.46

6.03

6.47

13.7

14.9

31

Static power/W

PD

No-load

-

12

-

10.1

-

10.2

32

Output protection current/A

IImax

Output voltage decline to 95%

81.6

108

81.6

104

34

43.5

33

Short-circuit currenta/A

IS

TA=25℃,Vout<250mV

56

108

56

104

23.3

43.5

continuación tabla 3 (b) características eléctricas

No.

Character

Symbol

Conditions

(Unless otherwisespecified ,-55℃≤Tc≤125℃,VIN=28V±5%)

MV24A15M400B

MV24A24M400B

MV24A28M400B

Min

Max

Min

Max

Min

Max

1

Input transient voltagea/V

VIS

TA=25℃,less 100ms

-

50

-

50

-

50

2

Input under-voltage /V

turn-on voltage

VINL-ONT


VINL-OFF


-

17.9

-

17.9

-

17.9

turn-off voltage

14.8

-

14.8

-

14.8

-

3

Input over turn-off/on

VINL-ON/OFF


36.3

39.6

36.3

39.6

36.3

39.6

4

Inhibitedinput current/mA

IINH

TA=25℃

-

15.0

-

15.0

-

15.0

5

Bias voltage for PC port/V

VPC

TA=25℃,IPC=1.0mA

5.50

6.50

5.50

6.50

5.50

6.50

6

Current for PC porta/mA


IPC

TA=25℃,VPC=5.5V

1.5

3.0

1.5

3.0

1.5

3.0

7

Inhibitedfunction  for PC port/mV

VINH-PC

TA=25℃

2.3

2.9

2.3

2.9

2.3

2.9

8

Turn-on delay for PC porta/ms

Td(ON)

TA=25℃

-

7

-

7

-

7

9

alarm voltage for PC porta/V

peak/V

VA-PC

TA=25℃

Alarm will be turn on when  input under-voltage or input over voltage

-

6.5

6.5

6.5

period/ms

TPC

1

10

1

10

1

10

pulse/μs

WPC

350

450

350

450

350

450

10

Resistance for PC porta/MΩ

RI-PC

TA=25℃

0.9

1.1

0.9

1.1

0.9

1.1

11

Output voltage amplitude for PR/V

Vout-PR

TA=25℃,PR load over 30Ω,capacitance less 30pF

5.7

6.1

5.7

6.1

5.7

6.1

12

Output current for PR port

Iout-PR

TA=25℃

150

-

150

-

150

-

13

Impedance for PR port inputa/Ω

ZI-PR

TA=25℃

375

625

375

625

375

625

14

Input voltage threshold vale for PR porta/V

VI-PR

TA=25℃,Pulse width≥20ns

2.4

2.6

2.4

2.6

2.4

2.6

15

Drive capabilitya/pc

N

TA=25℃,no buffer amplifier circuit

-

3

-

3

-

3

16

Power distribution precision a/%

PE

TA=25℃,load≥10%

-

5

-

5

-

5

17

SC reference voltage/V

Vb-SC

TA=25℃,relative negative output

1.21

1.25

1.21

1.25

1.21

1.25

18

SC alarm voltagea/V

VA-SC

TA=25℃,SC alarm will be turn on when input under-voltage or output over-voltage()

-

0.5

-

0.5

-

0.5

19

Induct offset voltagea/V

VSC

TA=25℃,each terminal<0.25V(induction terminal is closed)

-

0.5

0.5

0.5

20

Isolation voltage(Ac RMS)/V

VISO

TA=25℃,10s

Between input and output

3000

-

3000

-

3000

-

Between input and baseboard

1500

-

1500

-

1500

-

Between output and baseboard

500

-

500

-

500

-

21

Isolation resistance/MΩ

RISO

TA=25℃,add 500V(DC)between input and output, add 500V(DC)between pin and baseboard

10

-

10

-

10

-

22

Output voltage

Vout

TA=25℃,full-load

14.85

15.15

23.76

24.24

27.72

28.28

23

Output current

Iout


0

26.67

0

16.67

0

14.29

24

Voltage regulation/%

Sv

18 36, full-load

-

0.20

-

0.20

-

0.20

25

Load regulation/%

Sin

No-load full-load

-

0.40

-

0.20

-

0.20

26

Temperature coefficient/(%/℃)

Av


-

0.005

-

0.005

-

0.005

27

Output voltage regulation range/%

VTR

TA=25℃,load≥10%

10

110

10

110

10

110

28

efficiency/%

η

TA=25℃,full-load

86.1

-

87

-

86

-

29

Ripple voltage and noise voltage (peak-peak value)/mV

VR

BW≤20MHz,full-load

-

75

-

100

-

215

30

Output over-voltage protection point/V

Vovp

TA=25℃

17.1

18.5

27.1

29.1

31.5

33.9

31

Static power/W

PD

No-load

-

9.4

-

12

-

9.5

32

Output protection current/A

IImax

Output voltage decline to 95%

27.2

34.8

17.0

21.7

14.5

19.4

33

Short-circuit currenta/A

IS

TA=25℃,Vout<250mV

18.6

37.9

2.25

21.7

10.0

19.4

una garantía de diseño, la prueba solo será necesaria cuando la inspección o los parámetros identificados se efectúen al cambiar el proceso

5 Diagrama de bloques de circuito del convertidor de CC-CC Mil-COTS serie MV24A


6 Curva de característica típica del convertidor de CC-CC Mil-COTS serie MV24A


Diagrama 3 Eficiencia (Potencia de salida)
(Modelo MV24A5M200B)

7 Curva de MTBF del convertidor de CC-CC Mil-COTS serie MV24A


Diagrama 4 Curva MTBF
(Prediciendo que el terreno está en buenas condiciones, este diagrama corresponde al modelo MV24A5M400B)

Designación de 8 pines del convertidor de CC-CC Mil-COTS serie MV24A


Figura 5 Vista inferior del pin hacia afuera

Tabla 4 Designación de pines

Pin

Symbol

Designation

1

+In

Positive Input

2

PC

Prohibit/Alarm

3

PR

Parallel

4

- In

Negative Input

5

- Out

Negative Output

6

- Sence

Negative Induction

7

SC

Secondary Side Control

8

+ Sence

Positive Induction

9

+Out

Positive Output


9 Diagrama de conexión típico del convertidor CC-CC DC-Series de la serie MV24A

(1) Diagrama de conexión del circuito de prueba eléctrica (diagrama 6)

Diagrama 6: diagrama de conexión del circuito de prueba eléctrica

(2) Prohibición de PC y alarma de falla (Diagrama 7 ~ 9)
El puerto de PC es un puerto bidireccional, que tiene la función habilitada para el módulo y la función de indicación de falla.

Diagrama 7: Módulo habilitado Diagrama 8: Indicador de estado e Indicación de falla
La salida se inhibirá cuando (-In) del puerto de PC menos 2.3V, la frecuencia de repetición de este pin sea mayor a 1s
El indicador LED se enciende cuando el módulo está en funcionamiento normal; el indicador parpadea cuando ocurre sobretensión o bajo voltaje. El puerto de PC emitirá señal como el diagrama 9 cuando ocurre una falla.

Diagrama 9: señal de falla
(3) Función paralela (N + M)
Se realizó la función de corriente en paralelo y expansión al conectarse con puertos PR de módulos, al mismo tiempo, también se acepta la función tolerante a fallas. Hay dos métodos para realizar el paralelismo y la expansión de la función actual, uno es el modo maestro-esclavo automático (Diagrama 10) y el otro es el modo maestro-esclavo (diagrama 11). En el modo maestro-esclavo, el voltaje de salida del paralelismo puede ser ajustable por el puerto SC del módulo maestro en el área de aceptación. Incluso si ambos métodos pueden ampliar la potencia de salida, el método del diagrama 10 es mejor para la redundancia del sistema. El método del diagrama 11 es mejor para el área en grandes interferencias electromagnéticas. Debe señalarse que la matriz de células puede ser aplastada por el módulo maestro desactivado.

Diagrama 10: Paralelo y corriente de expansión

Diagrama 11: Paralelo y expansión de corriente (maestro-esclavo)

(4) Regulación de voltaje de salida
Conectado como diagrama 12, el valor de la tensión de salida y la resistencia RW1 se deciden por la fórmula siguiente


Diagrama 12: ajuste positivo de la tensión de salida


Conectado como en el diagrama 13, el valor de la tensión de salida y la resistencia RW2 se deciden por la siguiente fórmula


Diagrama 13: ajuste negativo del voltaje de salida

10. Especificaciones del paquete del convertidor de CC-CC Mil-COTS serie MV24A


Diagrama 14: Diagrama esquemático del paquete (vista ascendente)

Tabla 5 Descripción del paquete

Symbols

Unit/mm

Minimum

Typical

Maximum

A

12.20

-

13.50

A1

2.80

-

3.30

A2

10.65

-

11.40

Φb1

3.68

-

3.94

Φb2

1.90

-

2.16

D

116.42

-

58.28

E

43.95

-

44.95

e2

-

17.78

-

e3

-

7.62

-

e1

-

106.68

-

L

4.58

-

-

X1

45.45

-

45.95

Y1

50.55

-

51.05

d

3.17

-

3.55

Y

55.65

-

56.15



11 Información sobre pedidos de MV24A Series Mil-COTS DC DC Converter


Diagrama 15: información sobre pedidos

Notas de aplicación:

  • El punto de detección de voltaje debe mantenerse en la raíz del pin del producto de prueba.
  • No conecte el producto con electricidad.
  • Antes de encender el producto de prueba, debe confirmar la polaridad de la fuente de alimentación para evitar daños a los productos por mala conexión. Al mismo tiempo, asegúrese de que el voltaje de la fuente de alimentación y la corriente de carga no excedan la limitación de uso del producto de prueba.
  • Los pines no utilizados deben colgarse en el aire durante ninguna operación.
  • Los pasadores en el terminal de inhibición deben colgarse en el aire durante ninguna operación.
  • PC y PR no pueden conectarse con + In y -In, SC no puede conectarse directamente con + Vout. De lo contrario, el producto puede dañarse.
  • Cuando ordene este dispositivo, las especificaciones eléctricas detalladas se basarán en los estándares relevantes.


nos pondremos en contacto con usted dentro de las 24 horas.


Productos relacionados
Model Series Max. Output Power (W) Input DC Voltage (V) Output Voltage (V)

Convertidores CC-CC Mil-COTS de la serie M24C

100W 18V ~ 36V 3.3V, 5V, 12V, 15V

Convertidores de CC CC Mil-COTS serie MV48C

100W, 150W 36V ~ 75V 3.3V, 5V, 12V, 15V, 24V, 28V

Convertidores CC DC Mil-COTS de la serie MV24A

100W 18V ~ 36V 3.3V, 5V, 12V, 15V, 24V, 28V

Convertidores CC de alta tensión de la serie de entrada 270V

150W, 300W 155V ~ 425V 5V, 15V, 48V

MV24B Series Mil-COTS DC DC Converters

150W, 200W 18V-36V 3.3V, 5V, 12V, 15V, 24V, 28V

Convertidores M24B28M250B Mil-COTS DC DC

250W 18V ~ 36V 28V